Systems
for Electronic & Control System Studies
Solartron Analytical Frequency Response Analyzers are widely used
for testing the phase and magnitude transfer function of both purely
electrical and mixed systems. In these experiments the FRA's
generator output (essentially a sinusoidal oscillator) is connected
either directly to the system under test, or via an
electromechanical transducer (e.g. a solenoid). The response of the
system to the applied oscillation is then connected, either by
direct electrical connection or via another transducer (e.g. a
microphone) to the analyzer input of the FRA.
The overall transfer function of the system can then be measured
over the operating frequency range of the FRA.
Typical applications include:
- Transfer functions involving an electrical
response, e.g. resonators (crystal, ceramic, supersonic),
magnetic head (audio, video) delay lines, capacitors/varistors/resistors,
piezo/ferroelectric materials, communication cables, switched
mode power supplies
- Transfer functions involving a non-electrical
response, e.g. electrohydrodynamical
- Transfer functions involving a non-electrical
perturbation, e.g. mechanical, pressure, temperature, magnetic
field
- Transfer functions involving both non-electrical
perturbation and response, e.g. photoelectrochemical impedance
spectroscopy
Frequency Response Analyzers
Model 1260A

|
Impedance/Gain-phase Analyzer
10 µHz to 32 MHz operating frequency range,
0 - 3 V/0 - 60 mA rms
voltage/current generator output, 0.015 ppm frequency
resolution, 0.1% magnitude and 0.1 degree accuracy,
0.001 dB and 0.01 degree resolution, built-in
current converter allowing direct impedance measurements up
to > 100 MΩ, 2 and 4 terminal measurement
configurations, can apply polarization voltages in range +/-
40.95 V. Singe-sine detection mode. Manual or computer
control via IEEE488 (GPIB) interface
Click here for
more information
|
|
Model 1255A

|
Frequency Response Analyzer
10 µHz to 20 MHz operating frequency range,
0 - 3 V voltage generator output,
0.015 ppm frequency resolution, 0.2% magnitude and 0.2
degree accuracy, 0.001 dB and 0.01 degree
resolution, built-in current converter allowing impedance
measurements up to > 100 MW,
2, 2 and 4 terminal measurement configurations, can apply
polarization voltages in range +/- 40.95 V. Singe-sine
detection mode. Manual or computer control via IEEE488
(GPIB) interface.
Click here for
more information
|
|
Model 1255B

|
Frequency Response Analyzer
10 µHz to 1 MHz operating frequency range,
0 - 3 V voltage generator output,
10 µHz max. frequency resolution, 0.2% magnitude and
0.2 degree accuracy, 0.02 dB and 0.2 degree
resolution, can apply polarization voltages in range +/-
40.95 V. Singe-sine detection. Computer control only
via IEEE488 (GPIB) interface.
Click here for
more information
|
|
Model 1252A

|
Frequency Response Analyzer
10 µHz to 300 kHz operating frequency range,
0 - 3 V voltage generator output,
10 µHz max. frequency resolution, 0.2% magnitude and
0.2 degree accuracy, 0.02 dB and 0.2 degree
resolution, can apply polarization voltages in range +/-
40.95 V. Singe-sine detection mode. Computer control
only via IEEE488 (GPIB) interface.
Click here for
more information
|
|
Model 1250A

|
Frequency Response Analyzer
10 µHz to 65 kHz operating frequency range,
10 µHz max. frequency resolution, 1% magnitude and 3
degree accuracy, 0.02 dB and 0.2 degree
resolution, can apply polarization voltages in range +/-
10.23 V. 30 mV to 300 V FS sensitivity,
singe-sine detection mode. Optional synchronizer input.
Optional modulator/demodulator function. Manual or computer
control via IEEE488 (GPIB) interface.
Click here for
more information
|
|
Model 1250B

|
Frequency Response Analyzer
10 µHz to 65 kHz operating frequency range,
10 µHz max. frequency resolution, 1% magnitude and 3
degree accuracy, 0.02 dB and 0.2 degree
resolution, can apply polarization voltages in range +/-
10.23 V. 30 mV to 300 V FS sensitivity,
singe-sine detection mode. Optional synchronizer input.
Optional modulator/demodulator function. Computer control
only via IEEE488 (GPIB) interface.
Click here for
more information
|
|
Model 1254A

|
Frequency Response Analyzer -
Four Analyzer Channels
10 µHz to 65 kHz operating frequency range,
10 µHz max. frequency resolution, 1% magnitude and 3
degree accuracy, 0.02 dB and 0.2 degree
resolution, can apply polarization voltages in range +/-
10.23 V. 30 mV to 300 V FS sensitivity,
singe-sine detection mode. Four analyzer channels. Optional
synchronizer input. Optional modulator/demodulator function.
Manual or computer control via IEEE488 (GPIB) interface.
Click here for
more information
|
|
Model 1253A

|
Frequency Response Analyzer
1 mHz to 20 kHz operating frequency range,
1 mHz max. frequency resolution, 1% magnitude and 1
degree accuracy, 0.02 dB and 0.2 degree
resolution, can apply polarization voltages in range +/-
10.22 V. Singe-sine detection mode. Manual or computer
control via IEEE488 (GPIB) interface.
Click here for
more information
|
top of page
|